1. DC VOLTAGE
Range : 600mV – 1000V
Accuracy : ±(0.5% + 3 digits) / ±(0.8% + 10 digits )
Resolution : 0.1mV – 1V
Input Impendence
About10MΩ
Overload protection
200mVrange: 550VDCorAC peak value
Other ranges: 1000V DC o rAC750V peak value
2. AC VOLTAGE (TRMS)
Range : 600mV – 750V
Accuracy : ±(0.8% + 5 digits) / ±(1.2% + 10 digits)
Resolution : 0.1mV – 1V
Input Impendence
About 10MΩ
Standard sine wave and triangular wave
40Hz–1KHz
Other wave form
40Hz–200Hz
3. DC CURRENT
Range : 600µA – 6000µA
Accuracy : ±(0.8% + 10 digits)
Resolution : 0.1µA / 0.001mA
Maximum measurement voltage drop
600mV
Overload protection
600µA/6000µA ,0.6A/250V resettable fuse
Positive input terminal
VΩ
Negative input terminal
COM
Frequency response
Sin wave and Triangular wave: 40Hz–1Kz
Other waveform
40Hz-200Hz
4. AC CURRENT
Range : 600µA – 1000A
Accuracy : ±(0.8% + 10 digits) / ±(2% + 30 digits)
Resolution : 0.1µA – 1A
Maximum measurement voltage drop
600mV
Overload protection
600µA/6000µA ,0.6A/250V resettable fuse
Positive input terminal
VΩ
Negative input terminal
COM
Standard sine wave and triangular wave
40Hz–1KHz
Other waveform
40Hz–200Hz
5. RESISTANCE
Range : 600Ω – 60MΩ
Accuracy : ±(0.8% + 5 digits) / ±(0.8% + 3 digits) / ±(1% + 25 digits)
Resolution : 0.1Ω – 10kΩ
Overload Protection
550V DC or AC peak value
Open circuit
<3V
6. FREQUENCY
Range : 10Hz – 20Mhz
Accuracy : ±(0.1%+3 digits)
Resolution : 0.01Hz – 10kHz
Overload protection
550V DC or AC peak (<10s)
Input sensitivity RMS
Effective value 1V
7. CAPACITANCE
Range : 60nF – 6000uF
Accuracy : ±(3.5%+20 digits) / ±(5%+10 digits)
Resolution : 10pF – 1uF
Overload protection
550V DC or AC peak (<10s)
8. TEMPERATURE
Range : (-50~1000)°C / (0~1832)°F
Accuracy : ±( 1% + 5) <400°C / ±(0.75% + 5) <750°F
Resolution : 1°C / 1°F
This 3 5/6 digits display and 6000 counts Clampmeter is a stable and battery powered meter. It adopts 20mm LCD screen making the readings clear and with 15 seconds backlit display and overload protection, it is easier to use. It can be used to test DC voltage, AC voltage, AC current, resistance, capacitance, diode, temperature, continuity and frequency. To assure high accuracy and resolution, it adopts a 8-bit micro-processor and a dual integral A/D convertor IC. It is an ideal tool for industries, radio technology, educational institutions, electricians, engineers, technicians, manufacturers, and for household use. This product comes with one user manual, Carrying pouch, a pair of test leads, one temperature probe and one 9V battery.
1. DC VOLTAGE
Range : 600mV – 1000V
Accuracy : ±(0.5% + 3 digits) / ±(0.8% + 10 digits )
Resolution : 0.1mV – 1V
Input Impendence
About10MΩ
Overload protection
200mVrange: 550VDCorAC peak value
Other ranges: 1000V DC o rAC750V peak value
2. AC VOLTAGE (TRMS)
Range : 600mV – 750V
Accuracy : ±(0.8% + 5 digits) / ±(1.2% + 10 digits)
Resolution : 0.1mV – 1V
Input Impendence
About 10MΩ
Standard sine wave and triangular wave
40Hz–1KHz
Other wave form
40Hz–200Hz
3. DC CURRENT
Range : 600µA – 6000µA
Accuracy : ±(0.8% + 10 digits)
Resolution : 0.1µA / 0.001mA
Maximum measurement voltage drop
600mV
Overload protection
600µA/6000µA ,0.6A/250V resettable fuse
Positive input terminal
VΩ
Negative input terminal
COM
Frequency response
Sin wave and Triangular wave: 40Hz–1Kz
Other waveform
40Hz-200Hz
4. AC CURRENT
Range : 600µA – 1000A
Accuracy : ±(0.8% + 10 digits) / ±(2% + 30 digits)
Resolution : 0.1µA – 1A
Maximum measurement voltage drop
600mV
Overload protection
600µA/6000µA ,0.6A/250V resettable fuse
Positive input terminal
VΩ
Negative input terminal
COM
Standard sine wave and triangular wave
40Hz–1KHz
Other waveform
40Hz–200Hz
5. RESISTANCE
Range : 600Ω – 60MΩ
Accuracy : ±(0.8% + 5 digits) / ±(0.8% + 3 digits) / ±(1% + 25 digits)
Resolution : 0.1Ω – 10kΩ
Overload Protection
550V DC or AC peak value
Open circuit
<3V
6. FREQUENCY
Range : 10Hz – 20Mhz
Accuracy : ±(0.1%+3 digits)
Resolution : 0.01Hz – 10kHz
Overload protection
550V DC or AC peak (<10s)
Input sensitivity RMS
Effective value 1V
7. CAPACITANCE
Range : 60nF – 6000uF
Accuracy : ±(3.5%+20 digits) / ±(5%+10 digits)
Resolution : 10pF – 1uF
Overload protection
550V DC or AC peak (<10s)
8. TEMPERATURE
Range : (-50~1000)°C / (0~1832)°F
Accuracy : ±( 1% + 5) <400°C / ±(0.75% + 5) <750°F
Resolution : 1°C / 1°F
Brand | Hty |
---|---|
Power Source | Battery Powered |
Style | Clamp Meter |
Item Weight | 190 Grams |
Item dimensions L x W x H | 20 x 8 x 4.5 Centimeters |
Specification Met | CE, RoHS |
Measurement Type | Clamp Meter, Multimeter |
Manufacturer | SHREYANS ENTERPRISES, 002, 9th Avenue Business Park, Chamrajpet 5th Main Road, Bangalore, India |
Country of Origin | India |
Model number | B-6010 |
Number of Memory Sticks | 6010 |
Item Weight | 190 g |
Product Dimensions | 20 x 8 x 4.5 cm; 190 g |
Item model number | B-6010 |
Item Height | 4.5 Centimeters |
Item Width | 8 Centimeters |
Included Components | Clampmeter and Testing Leads with Manual User guide |
• Display: LCD
• 6000 Counts
• 3 5/6 Digits
• AC & DC Voltage
• AC Current
• DC Current upto 6000uA
• Sampling rate 3 times
• Wide Jaw Size
• True-RMS
• Resistance
• Capacitance
• Frequency
• Temperature
• Auto Negative polarity indication: Displaying “-”
• Continuity Buzzer
• Duty Cycle
• Data Hold
• Diode Test
• Large LCD Display
• Low Battery Indication
• Auto Power Off
ASIN | B0DK745NLM |
---|---|
Best Sellers Rank | #54,749 in Industrial & Scientific (See Top 100 in Industrial & Scientific) #172 in Clamp Meters |
Date First Available | 17 October 2024 |
Manufacturer | SHREYANS ENTERPRISES, 002, 9th Avenue Business Park, Chamrajpet 5th Main Road, Bangalore, India |
Packer | avsCARTindia New Delhi-110007, Email: avsenterprises16@gmail.com |
Item Dimensions LxWxH | 20 x 8 x 4.5 Centimeters |
Net Quantity | 1 Set |
Generic Name | CLAMP METER |
100% Original product that covered warranty by the vendor.
You have the right to return your orders within 30 days.
Your orders are shipped seamlessly between countries.
Your payments are secure with our private security network.
Copyright © 2024 BEETECH, All rights reserved. Design by Dotclick