| 1. DC VOLTAGE | Range : 600 mV - 600V |
| Accuracy : ±(1.0% + 2 digits) / ±(0.8% + 3 digits) |
| Resolution : 0.1mV - 0.1V |
| Input Resistance | About 10MΩ |
| Max. Input Voltage | 600V DC |
| 2. AC VOLTAGE (TRMS) | Range : 6 V - 600V |
| Accuracy : ±(0.8% + 3 digits) |
| Resolution : 0.001V - 0.1V |
| Input Resistance | About 10MΩ |
| Frequency range | 40Hz – 400Hz -Response: True RMS |
| Max. Input Voltage | 600V AC (effective value) |
| 3. AC CURRENT | Range : 6 A - 600A |
| Accuracy : ±(3.0% + 6 digits) |
| Resolution : 0.01A - 0.1A |
| Frequency Range | 40Hz ~ 400Hz – Response: average value. |
| Max. Input Current | 600A DC |
| Max. Input Current | 600A AC |
| 4. RESISTANCE | Range : 600Ω - 60MΩ |
| Accuracy : ±(0.8% + 3 digits) / ±(1.2% + 3 digits) |
| Resolution : 0.1Ω - 0.1MΩ |
| Open Circuit voltage | approx.. 0.4V |
| Overload Protection | 250V DC or AC (valid value) |
| 5. CAPACITANCE | Range : 6nF - 60mf |
| Accuracy : ± (4.5%+5 digits) |
| Resolution : 0.1nF - 0.01mF |
| 6. FREQUENCY | Range : 10Hz - 10Mhz |
| Accuracy : ±(0.5% + 2 digits) |
| Resolution : 0.001Hz - 0.001Mhz |
| 7. FREQUENCY (When measuring current, through the clamp) | Range : 10Hz - 1kHz |
| Accuracy : ±(1.5% + 5 digits) |
| Resolution : 0.01Hz - 0.001kHz |
| Max. Input Current | 600A |
| Input signal range | 4A AC (T-RMS) |
| 8. FREQUENCY (V-GEAR) (When measuring voltage) | Range : 10Hz - >1kHz |
| Accuracy : ±(1.5% + 5 digits) |
| Resolution : 0.01Hz - 0.001kHz |
| Input Resistance | About 10MΩ |
| Input Voltage range | 0.2V AC (RMS) |
| Max. Input Voltage | 600V AC (valid value) |
| 9. TEMPERATURE | Range : -50°C ~ 1300°C / -58°F ~ 2372°F |
| Accuracy : 土1% + 3 digits) |
| Resolution : 1°C / 1°F |
| Overload protection | 250V DC or AC (valid value) |
| 10. DIODE TEST | Display approximate for ward voltage of diode |
| • Forward DC Current is about 1mA |
| • Reverse DC voltage is about 3.3V |
| 11. CONINUITY TEST | Beeper sounds when resistance is less than 50 OHMS (open circuit voltage about 2.1V) |