....a name to trust for performance and satisfaction....
 
UTG-01+
Transducer choice | Φ10mm 2.5MHz Transducer. Φ10mm 5.0MHz Transducer |
Display | 4-digital LCD display |
Minimum display unit | 0.1mm |
Working frequency | 5MHz/2.5MHz |
Measuring range | 1.2 to 220mm (steel) |
Minimum limit for tube curvature measurement | Audio 20*3mm (steel) |
Accuracy | +/-(1%H+0.1)mm, H denotes the measured thickness |
Sound velocity range | 1000 to 9999 m/s |
Measuring sound velocity with a given thickness | measuring range : 1000 to 9999 m/s. When the given thickness over 20mm, the accuracy is +/-5%; given thickness when the given thickness less than 20mm, the accuracy is +/-1mm/H*100% |
Operation temperature | 0°C to 40°C |
Power Supply | 3*1.5V AAA alkaline batteries |
Operation current | Normal operation current≤50mA With Backlight turn on current ≤120mA Stand-by current : ≤20uA |
Size | 70.0*135*38mm |